Server, Network
& Telecom Racks

Custom rack cabinets and equipment housings manufactured around your hardware, installation space and service-access requirements.

SRG International Pvt. Ltd. brings in-house sheet-metal fabrication, forming, welding and finishing to IT, networking, telecom and industrial equipment projects.

Floor-standing server and network cabinets with equipment rails, perforated doors and a wall-mounted network cabinet
Product configuration reference. Equipment and final cabinet specification are agreed separately.
Choose the installation

The right cabinet starts with the equipment.

01 / FLOOR STANDING

Server rack cabinets

For server rooms, equipment rooms and industrial IT installations. Discuss usable mounting height, equipment depth, mounting rails, door access, cable routing and floor support.

Specify: equipment list, maximum equipment depth, installed weight and maintenance access.

02 / WALL MOUNTED

Network rack cabinets

For switches, patch panels and network distribution points in offices, retail premises, institutions and factories. Cabinet depth, cable entry and access should suit the installed equipment.

Specify: wall construction, fixing arrangement, patching space and service clearances.

03 / OPEN FRAME

Open-frame equipment racks

Discuss open-frame configurations where direct access and cable visibility are preferred. Frames, mounting interfaces and floor fixing are developed around the equipment and project scope.

Specify: mounting pattern, equipment support, cable management and installation environment.

04 / CUSTOM TELECOM

Telecom & equipment cabinets

Custom cabinet fabrication for communication, electronic and industrial control equipment. Indoor and outdoor requirements need different ventilation, sealing and corrosion-protection choices.

Specify: environment, heat-management needs, mounting plates and requested ingress-protection target.

Infitra rack catalogue

Two rack families. Defined size choices.

Floor-standing server racks

U heights: 12U, 15U, 17U, 20U, 22U, 24U, 27U, 30U, 32U, 36U, 42U, 45U.

Outside widths: 600 mm or 800 mm.
Depths: 600 mm, 800 mm, 1000 mm or 1200 mm.

42U configuration reference

600 mm wide × 1000 mm deep, with front glass door, rear steel door, detachable side panels and wheels.

  • Fan housing unit for four fans
  • Sliding/rotary keyboard tray and monitor shelf
  • Additional equipment shelf and horizontal cable manager
  • 12-socket, 5 A power strip
  • Equipment mounting hardware

Select the standard-accessory button in the enquiry form to request this package, or choose accessories individually. The quotation confirms quantities, electrical specifications and included items.

Wall-mount networking, DVR & AV racks

U heights: 2U, 4U, 6U, 9U, 12U, 15U.
Construction: single-section or double-section.

Outside widths: 550 mm or 600 mm, with an internal 19-inch equipment-mounting arrangement.
Depths: 400 mm, 500 mm, 600 mm or 650 mm.

Lockable tempered-glass front door; rear-open wall-mount provision for the single-section configuration. Double-section mounting and rear-access details are confirmed in the drawing.

Catalogue construction: welded CRCA steel, 1.0 mm body sheet and 1.6 mm mounting angles; top and bottom cable entry, side ventilation perforations and provision for two fans.

Stated static load: up to 30 kg for the configured wall cabinet, subject to the selected model, load distribution and approved wall/fixing arrangement. This is not a rating for every rack or wall type.

6U configuration reference

  • Front glass door with key lock
  • Horizontal cable manager and mounting hardware
  • 6-socket, 5 A power strip
  • One-fan housing arrangement; two-fan option available

Available accessory choices include a cantilever tray, fixed shelf, cooling fans, PDU, cable managers, blank panels and mounting hardware. Applications include computer networking, DVR, audio-visual, TV/radio broadcasting, telecom and other compatible 19-inch equipment.

U height describes equipment mounting space, not the full outside cabinet height. The form’s outside-height estimate is for layout discussion; manufacturing dimensions, load suitability, accessories and electrical fit-out are confirmed in the agreed quotation and drawing.

Specification guide

What we need to quote accurately.

Rack height, outside dimensions and equipment compatibility are different requirements. Share what you know; our team can review the remaining details before quotation.

RequirementWhat to shareWhy it matters
Rack height in URequired usable mounting height and future expansionDefines the vertical equipment-mounting requirement, not the total outside cabinet height.
Width, depth & heightOutside dimensions, room space and access routeChecks cabinet footprint, doors, installation access and servicing space.
Mounting compatibilityEquipment mounting drawings, rail spacing and support needsConfirms fit before manufacture; do not select by outer dimensions alone.
Equipment depth & loadDeepest equipment, loaded weight and weight distributionInforms rail positioning, shelves, base and fixing requirements.
Doors & ventilationPerforated, solid or project-specific door arrangement; heat-management needsCoordinates access, airflow and protection with the installed equipment.
Cable managementTop/bottom entries, routing, patching and gland requirementsHelps plan usable equipment and cable space.
AccessoriesShelves, trays, fan provision, PDU mounting, levelling feet, castors and earthing pointsAccessories and electrical equipment are included only when agreed in the scope.
Material & finishSteel/GI or stainless-steel grade, thickness and powder-coating colourMatches construction and finish to the installation environment.
Custom manufacturing

Built around the drawing.
Not a guessed specification.

We review cabinet construction, equipment interfaces, hardware, access and finishing requirements before manufacture. Our Faridabad manufacturing capability supports custom sizes, prototypes and repeat production, subject to the agreed scope.

  • CNC cutting, punching and bending for sheet-metal components
  • Welded assemblies, mounting arrangements and access panels
  • In-house powder coating, assembly, inspection and packing
  • Drawing and specification review before production
Explore our manufacturing capability ↗

Protection & electrical scope

IP protection is a requested design target—not an automatic rating. Door seals, openings, glands and any required testing must support the stated protection level.

Electrical fit-out, PDUs, fans, networking equipment, active cooling, testing and installation are supplied only where specifically included in the quotation.

Project coverage

Faridabad and Delhi NCR, including Delhi, Gurugram, Noida and Greater Noida, with project support across Manesar, Bawal, Palwal, Kosi Kalan and Mathura. North India and wider shipping are reviewed against the project scope and site readiness.

Common questions

Plan the rack before placing the order.

Do you manufacture custom server and network racks?

Yes. SRG International manufactures cabinet structures and rack assemblies to agreed dimensions, mounting interfaces, material, hardware and finish requirements.

Can I specify rack height in U?

Yes. Share the required U height together with outside size limits and equipment depth. Final mounting and usable space are confirmed on the approved drawing.

Are accessories and electrical equipment included?

Only those listed in the agreed quotation. Specify shelves, cable management, fan provision, PDU mounting and any electrical fit-out separately.

What should I send for a quotation?

Send rack type, U height, outside dimensions, equipment details, loaded weight, quantity, project city and timeline. Drawings or equipment datasheets help confirm compatibility.

Start a conversation

Tell us what
you need to build.

Share your project location, dimensions and intended use. Our team will review the requirement and discuss a suitable manufacturing solution.

CALL OUR TEAM+91 93117 72429EMAILinfo@srginternational.inMANUFACTURING BASE

Plot 13A, Industrial Area, Sector 4,
Ballabhgarh, Faridabad, Haryana 121004

PREFER WHATSAPP?Message our team ↗VISIT OUR FACTORYFactory location / Get directions ↗

Technical details are optional. Fill in what you know; our team can help with the rest.

You can also attach site photos or drawings in WhatsApp after opening your message.

Your details are shared with SRG International to respond to your enquiry. Email submissions are processed by FormSubmit. WhatsApp opens a prepared message; tap Send there to deliver it. Google Ads measurement uses cookies; form details are not included in the Google tag.

PIN lookup uses India Post postal records via the independent PostalPincode.in service.

Indoor, outdoor or custom IT racks: how do you choose?

Indoor server and network cabinets

Start with equipment depth, usable rail spacing, equipment weight, airflow, cable-management space and service access. Glass, perforated and solid doors have different cooling and access implications.

Outdoor and IP-target cabinets

Outdoor racks need a separate environmental brief: rain and dust exposure, solar heating, corrosion, cooling, seals, locks and cable entries. An IP designation applies to the verified enclosure configuration; an indoor rack does not become outdoor-rated by adding a solid door.

What is U height?

One rack unit (1U) is 44.45 mm of usable equipment-mounting height. U height is not the overall external cabinet height. Allow separately for the base, roof, cable space and selected accessories.

What does 19-inch mounting mean?

The nominal 19-inch equipment mounting format is different from the outside cabinet width. A 600 mm or 800 mm wide cabinet may use a compatible internal mounting system. Confirm the equipment and rail drawings, fixing pattern, usable depth and clearances.

Check width, depth and the complete installation envelope

Required cabinet depth must include the deepest equipment, front/rear connectors, cable bend radii, rails and doors. Check delivery access, opened-door space, loaded weight, floor or wall fixing and maintenance access before ordering. Select accessories in the enquiry form; electrical fit-out and quantities are included only when quoted.

Configuration guide · Dimensions and specification confirmed per project
Envelope guide only. Use the approved cabinet and equipment drawings for manufacturing and installation.